3Com Switch 7750 Series
Command Reference Guide – 802.1x
undo habp timer
View
System view
Parameter
interval: Interval (in seconds) to send HABP request packets. This argument ranges
from 5 to 600.
Description
Use the habp timer command to set the interval for a switch to send HABP request
packets.
Use the undo habp timer command to revert to the default interval.
The default interval for a switch to send HABP request packets is 20 seconds.
Use these two commands on switches operating as HABP servers only.
Example
# Configure the switch to send HABP request packets once in every 50 seconds
system-view
System View: return to User View with Ctrl+Z.
[3Com] habp timer 50
Chapter 2 HABP Configuration Commands
2-5
<3Com>