3Com Switch 7750 Series
Command Reference Guide – SNMP & RMON
View
Any view
Parameter
prialarm-entry-number: Extended alarm entry Index, in the range of 1 to 65535. If you
do not specify this argument, the configuration of all the extended alarm entries is
displayed.
Description
Use the display rmon prialarm command to display the configuration of a specified
RMON extended alarm entry or all the RMON extended alarm entries.
Related command: rmon prialarm.
Example
# Display the configuration of the extended RMON alarm entries.
<3Com> display rmon prialarm
Prialarm table 1 owned by abc is VALID.
Samples type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
Table 2-5 Description on the fields of the display rmon prialarm command
Prialarm table 1
abc
VALID
Samples type
Variable formula
Description
Sampling interval
Rising threshold
: delta
: 1.3.6.1.2.1.2.2.1.10.641
: ifInOctets.Ethernet1/0/1
: 10(sec)
: 100(linked with event 2)
: 10(linked with event 2)
: risingOrFallingAlarm
: 0
Field
Index number of a line of the extended alarm table
Creator of this extended alarm entry
The entry corresponding to the index is valid
Sample type: change value or absolute value
Alarm variable of the sampled node
Description of the alarm variable
Sampling interval
Rising threshold. An alarm is triggered when the
rising threshold is reached
2-6
Chapter 2 RMON Configuration Commands
Description