Remote Ping - 3Com 7750 Series Command Reference Manual

3com switch command reference guide
Hide thumbs Also See for 7750 Series:
Table of Contents

Advertisement

3Com Switch 7750 Series
Command Reference Guide – Remote Ping
Parameter
interval: Automatic test interval. It ranges from 0 to 65535 seconds and defaults to 0
meaning no automatic test.
Description
Use the frequency command to configure an automatic test interval.
Use the undo frequency command to disable automatic test.
The system automatically tests at intervals specified by this command, where the
argument interval is greater than 0.
Related command: count.
Example
# Set the automatic test interval of the "administrator-icmp" test group to 10 seconds.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] remote ping administrator icmp
[3Com-remote ping-administrator-icmp] frequency 10

1.1.5 remote ping

Syntax
remote ping administrator-name operation-tag
undo remote ping administrator-name operation-tag
View
System view
Parameter
administrator-name: Name of the administrator creating an Remote Ping test group, a
string of 1 to 32 characters.
operation-tag: Test operation tag, a string of 1 to 32 characters.
Description
Using the remote ping command, you can create an Remote Ping test group.
Executing this command allows the system to access Remote Ping test group view.
Example
# Create an Remote Ping test group, where the administrator name is "administrator"
and the test operation tag is "icmp".
<3Com> system-view
Chapter 1 Remote Ping Commands
1-6