Peer Timer; Preference - 3Com 7750 Series Command Reference Manual

3com switch command reference guide
Hide thumbs Also See for 7750 Series:
Table of Contents

Advertisement

3Com Switch 7750 Series
Command Reference Guide – Routing Protocol

5.1.53 peer timer

Syntax
peer { group-name | ip-address } timer keep-alive keepalive-interval hold
holdtime-interval
undo peer { group-name | ip-address } timer
View
BGP view
Parameter
group-name: Name of peer group, containing 1 to 47 characters.
ip-address: IP address of the peer.
Keepalive-interval: Keepalive timer in seconds. It is in the range of 1 to 65535 and
defaults to 60 seconds.
Holdtime-interval: Holdtime timer in seconds. It is in the range of 3 to 65535 and
defaults to 180 seconds.
Description
Use the peer timer command to configure the Keepalive and holdtime timers for a
peer/peer group.
Use the undo peer timer command to restore the default value of the timer.
The timer configured by using this command has a higher priority than the one
configured by using the timer command.
Example
# Configure Keepalive and Holdtime intervals of the peer group "test".
<3Com>system-view
System View: return to User View with Ctrl+Z.
[3Com] bgp 100
[3Com-bgp] peer test timer keep-alive 60 hold 180

5.1.54 preference

Syntax
preference ebgp-value ibgp-value local-value
undo preference
View
BGP view
Chapter 5 BGP Configuration Commands
5-47

Advertisement

Table of Contents
loading