Functions specific to SCALANCE
4.3 Panel button
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-faultmask
Result
The function of the button for setting the fault mask is enabled.
Further notes
You disable this function with the no panel-button control-faultmask command.
4.3.1.4

no panel-button control-faultmask

Description
With this command, you disable the following function of the button:
● If display mode D "fault mask" is displayed and the button is pressed for 5 - 12 seconds,
the fault mask is set.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no panel-button control-faultmask
Result
The function of the button for setting the fault mask is disabled.
136
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06