System time
5.3 SNTP client
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+
-
hh
mm
Enter the time difference as follows:
● with sign
● without spaces
● Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the show sntp
statuscommand.
5.3.3.3

sntp unicast-server ipv4

Description
With this command, you configure an SNTP unicast server.
Note
To avoid time jumps, make sure that there is only one time server in the network.
Requirement
● The addressing mode of the SNTP client is configured as "unicast".
● You are in the SNTP configuration mode.
The command prompt is:
cli(config-sntp)#
158
Description
Time zones to the west of the SNTP server time zone
Time zones to the east of the SNTP server time zone
Number of hours difference
Number of minutes difference
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06