The parameters have the following meaning:
Parameter
interface-type
interface-id
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Note
Differing port addresses
The first and second port must be configured on different interfaces.
Result
The ports of the ring redundancy are configured.
8.4.6.4

standby connection-name

Description
With this command, you assign a name to the standby connection on the device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby connection-name <string(32)>
The parameter has the following meaning:
Parameter
<string(32)>
Result
The standby connection is assigned a name.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Specifies the interface type for the first ring port
Specifies the number of the interface for the first ring port
Specifies the interface type for the second ring port
Specifies the number of the interface for the second ring port
Description
Name of the connection
Layer 2 management protocols
8.4 Ring redundancy and standby connection
Range of values / note
max. 32 characters