Time Set - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

The parameters have the following meaning:
Parameter
manual
ntp
sntp
SINEC
Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the show time command.
5.1.2.2

time set

Description
With this command, you set the system clock.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)> {january|february|march|april|may|
june|july|august|september|october|november|december}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter
hh:mm:ss
day
-
year
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
The system time is entered by the user
The system time is obtained from an NTP server
The system time is obtained from an SNTP server
The system time is obtained using the "SIMATIC time protocol"
Description
Time of day
Day of the month
Month
Year
System time
5.1 System time setting
Range of values / note
Hour, minute, second each sepa‐
rated by ":" no link
1 ... 31
january, february, march, april,
may, june, july, august, septem‐
ber, october, november, december
2000 ... 2035