Network structures
6.3 Spanning Tree
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
Further notes
You can reset the setting to the default with the no spanning-tree mst (properties)
command.
You display these settings and other information with the commands that start with show
spanning tree ....
6.3.5.13

no spanning-tree mst

Description
With this command, you reset the various properties of the Multiple Spanning Tree function to
the default value.
The default values are as follows:
Parameter
cost
port-priority
disable
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no spanning-tree mst<instance-id(1-64)>{cost|port-priority|disable}
252
Default value
● 200000 for physical interfaces
● 199999 for port channels
128
MST is disabled, RST is enabled