Layer 2 management protocols
8.4 Ring redundancy and standby connection
8.4.6.11

no standby wait-for-partner

Description
With this command, you disable the "Wait for standby partner" function on the device. A
standby connection is enabled even if the standby master has not yet established a connection
to the standby slave.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
no standby wait-for-partner
Result
The "Wait for standby partner" function is disabled.