Further notes
You enable this function with the rmon command.
You can display the status of this function and other information with the show rmon command.
12.4.2.3

rmon alarm

Description
With this command, you configure an alarm for monitoring a MIB variable. The variable is
checked at specific intervals to determine whether or not it has exceeded or fallen below
threshold values. Events are assigned to these occurrences.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
rmon alarm <alarm-number><mib-object-id(255)>
number(1-65535)]
number(1-65535)]
The parameters have the following meaning:
Parameter
alarm-number
mib-object-id
sample-interval-
time
absolute
delta
rising-threshold
value
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
<sample-interval-time(1-65535)>
{absolute|delta}
rising-threshold<value(0-2147483647)>[risingevent-
falling-threshold<value(0-2147483647)>[fallingevent-
[owner<ownername(127)>]
Description
Number of the alarm
OID of the MIB tag to be monitored
Interval for the check [s]
The current absolute value of the moni‐
tored MIB is evaluated
The difference between the current and
the previous value of the monitored MIB
is evaluated
Keyword for threshold value for rising or
high variable values
Relevant threshold value
Diagnostics
12.4 RMON
Range of values / note
1 ... 250
max. 255 characters
1 ... 65535
-
-
-
0 ... 2147483647
579