Siemens SCALANCE XB-200 Operating Instructions Manual

Siemens SCALANCE XB-200 Operating Instructions Manual

Hide thumbs Also See for SCALANCE XB-200:

Advertisement

SCALANCE XB-200
SIMATIC NET
Industrial Ethernet switches
SCALANCE XB-200
Operating Instructions
09/2015
C79000-G8976-C359-03
___________________
Introduction
___________________
Safety notices
___________________
Description of the device
___________________
Installation
___________________
Connecting up
___________________
Upkeep and maintenance
___________________
Technical specifications
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XB-200

  • Page 1 ___________________ SCALANCE XB-200 Introduction ___________________ Safety notices ___________________ SIMATIC NET Description of the device ___________________ Installation Industrial Ethernet switches SCALANCE XB-200 ___________________ Connecting up ___________________ Upkeep and maintenance Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Approvals 09/2015 C79000-G8976-C359-03...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Introduction

    Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XB-200 product group named above in the section on validity. There are two variants of each device, refer to the section "Product overview (Page 11)".
  • Page 4 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
  • Page 5 ● On the Internet under the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Catalogs You will find the order numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 6 Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 7: Table Of Contents

    Technical specifications of the SCALANCE XB213-3 (SC) ............ 42 Technical specifications of the SCALANCE XB213-3LD (SC) ..........44 Technical specifications of the SCALANCE XB213-3 ............46 Cable lengths .......................... 48 6.10 Switching properties ........................ 49 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 8 Table of contents Dimension drawings ..........................51 Approvals ............................. 55 Index ..............................61 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 9: Safety Notices

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 10 Safety notices SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 11: Description Of The Device

    6GK5 213-3BB00-2AB2 10/100 Mbps ST ports, multimode fiber- optic cable Factory settings EtherNet/IP variants ● Industrial Ethernet protocol: EtherNet/IP ● Base bridge mode: 802.1Q VLAN Bridge ● Redundancy mechanism: RSTP ● Trust mode: Trust DSCP SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 12 ● Base bridge mode: 802.1D transparent bridge ● Redundancy mechanism: Ring redundancy ● Trust mode: Trust COS Type designation The type designation of a SCALANCE XB-200 is made up of several parts that have the following meaning: Interfaces of devices with optical connectors: Interface...
  • Page 13: Device Views

    The following figure shows an overview of the components of the SCALANCE XB208. ① Electrical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ "RESET" button (rear) ⑤ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 14: Device View Of A Scalance Xb205-3

    The following figure shows an overview of the components of the SCALANCE XB205-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤ "RESET" button (rear) ⑥ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 15: Device View Of A Scalance Xb213-3

    The following figure shows an overview of the components of the SCALANCE XB213-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤ "RESET" button (rear) ⑥ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 16: Reset Button

    Description of the device 2.3 RESET button RESET button Position The "RESET" button is located on the rear of the SCALANCE XB-200. Figure 2-1 Position of the "RESET" button, for example on the SCALANCE XB213-3 Resetting the device to factory defaults...
  • Page 17 Using the WBM and CLI, you can enable or disable the button function. You will find detailed information about configuration of the button in the Configuration manuals (Page 3): ● SCALANCE XB-200 Web Based Management, section "Button" ● SCALANCE XB-200 Command Line Interface, section "Panel-Button" SCALANCE XB-200...
  • Page 18: Led Display

    Receiving data at port Not receiving data at port SC/ST ports There is an LED for each SC/ST port. LED color LED status Meaning Green Link exists, data reception at port No link exists SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 19: Installation

    The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 60664-1). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 20 "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components". You will find information on the system manuals in the section "Introduction (Page 3)", in "Further documentation". SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 21: Mounting On Din Rails

    2. Press the device down against the DIN rail until the spring catch locks in place 3. Fit the connectors for the power supply, see the section "Power supply (Page 25)". 4. Insert the terminal blocks into the sockets on the device. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 22 1. Disconnect all connected cables. ① 2. Release the DIN rail locking mechanism by pressing down on the release button ② 3. Pull the lower part of the device away from the DIN rail SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 23: Connecting Up

    Remove the protective caps only immediately before you use the plug-in connection. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 24 The LAN is designed either for “Environment A” according to IEEE802.3 or "Environment 0" according to IEC TR 62102. Do not connect any electrical connectors directly to the telephone network (telephone network voltage) or a WAN (Wide Area Network). SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 25: Power Supply

    Manufacturer: DEHN+SOEHNE GmbH+Co.KG, Hans-Dehn-Str.1, Postfach 1640, D92306 Neumarkt, Germany Operate the SCALANCE XB-200 with suitable overvoltage protection. Information on the power supply ● The power supply is connected using a 3-pin plug-in terminal block (spring-loaded terminal).
  • Page 26 Connecting up 4.2 Power supply Position and assignment Figure 4-1 Position of the power supply, for example on the SCALANCE XB213-3 Contact Assignment Assignment Contact 24 VDC 24 VDC Ground Ground Functional ground Functional ground SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 27: Serial Interface

    The connecting cable listed in the "Accessories" section has the following pin assignment: Contact Pin assignment of the RJ-11 plug Pin assignment of the D-sub female con- nector TD (Transmit Data) TD (Transmit Data) RD (Receive Data) SG (Signal Ground) RD (Receive Data) SG (Signal Ground) SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 28: Functional Ground

    With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 29: Upkeep And Maintenance

    Upkeep and maintenance Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Pressing the "RESET" button To load new firmware, you require the "RESET" button. When pressing the button, remember the information in the section "RESET button (Page 16)".
  • Page 30 "Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP Client". 8. Once the firmware has been transferred completely to the device and validated, there is an automatic restart on the device. This may take several minutes. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 31: Restoring The Factory Settings

    You will find detailed information on resetting the device parameters using the WBM and CLI in the configuration manuals (Page 3): ● SCALANCE XB-200 Web Based Management, section "Restart" ● SCALANCE XB-200 Command Line Interface, section "Reset and Defaults" SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 32 Upkeep and maintenance 5.2 Restoring the factory settings SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 33: Technical Specifications

    Housing, dimensions and weight Design compact Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 40 x 117 x 109 mm Weight 250 g Installation options Installation on a DIN rail SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 34 Technical specifications 6.1 Technical specifications of the SCALANCE XB208 Technical specifications Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 84 years SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 35: Technical Specifications Of The Scalance Xb205-3 (Sc)

    • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 300 mA Effective power loss at 24 VDC 7.2 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 36 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 55 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 37: Technical Specifications Of The Scalance Xb205-3Ld (Sc)

    (24 AWG) • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 290 mA Effective power loss at 24 VDC Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 38 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 50 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 39: Technical Specifications Of The Scalance Xb205-3

    • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 300 mA Effective power loss at 24 VDC 7.2 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 40 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 55 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 41: Technical Specifications Of The Scalance Xb216

    Dimensions (W x H x D) 80 x 117 x 109 mm Weight 400 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 60 years SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 42: Technical Specifications Of The Scalance Xb213-3 (Sc)

    • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 410 mA Effective power loss at 24 VDC 9.8 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 43 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 45 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 44: Technical Specifications Of The Scalance Xb213-3Ld (Sc)

    • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 400 mA Effective power loss at 24 VDC 9.6 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 45 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 40 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 46: Technical Specifications Of The Scalance Xb213-3

    • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 410 mA Effective power loss at 24 VDC 9.8 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 47 Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 45 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 48: Cable Lengths

    0 to 90 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE FC TP standard cable 0 to 100 m with IE FC RJ-45 Plug 180 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 49: Switching Properties

    1518 bytes Note The number of SCALANCE XB-200 modules connected in a line influences the frame delay. When a frame passes through the switch, this is delayed by the store-and-forward function of the SCALANCE XB-200 by 10-130 microseconds (at 100 Mbps).
  • Page 50: Scalance Xb

    Technical specifications 6.10 Switching properties SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 51: Dimension Drawings

    Dimension drawings Note Dimensions are specified in mm. Front view of the SCALANCE XB208 Figure 7-1 Width and height SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 52 Dimension drawings Front view of the SCALANCE XB205-3 (SC), XB205-3LD (SC), XB205-3 and XB216 Figure 7-2 Width and height based on the example of the SCALANCE XB205-3 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 53 Dimension drawings Front view of the SCALANCE XB213-3 (SC), XB213-3LD (SC) and XB213-3 Figure 7-3 Width and height based on the example of the SCALANCE XB213-3 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 54 Dimension drawings Side view of the SCALANCE XB-200 Figure 7-4 Depth SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 55 You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). → Entry type "Certificates"...
  • Page 56 Safety of electrical equipment In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive: ●...
  • Page 57 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 58 The products meet the requirements of the "Korean Standard". Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 59 ● ● SCALANCE XB205-3 ● ● SCALANCE XB205-3 (LD) ● ● SCALANCE XB205-3 (ST) ● ● SCALANCE XB216 ● ● SCALANCE XB213-3 ● ● SCALANCE XB213-3 (LD) ● ● SCALANCE XB213-3 (ST) ● ● SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 61: Index

    Grounding, 13, 14, 15, 28 SIMATIC NET glossary, 5 SIMATIC NET manual, 4 Spring-loaded terminal, 25 System manual, 4, 20, 56 Housing, 33, 36, 38, 40, 41, 43, 45, 47 WBM, 29 Web Based Management, 29 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
  • Page 62 Index Weight, 33, 36, 38, 40, 41, 43, 45, 47 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...

This manual is also suitable for:

Scalance xb-208Scalance xb205-3Scalance xb213-3

Table of Contents