Clear Counters - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show versions
Result
The version information of the entire system is displayed.
3.1.2

clear counters

Description
With this command, you reset the counters of an interface.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
clear counters [<interface-type><interface-id>]
The parameters have the following meaning:
Parameter
interface-type
interface-id
For information on identifiers of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If no parameters are specified, the counters for all interfaces are reset.
Result
The counters of the interface are reset.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Type or speed of the interface
Module no. and port no. of the interface
Configuration
3.1 System
Range of values / note
Specify a valid interface.
59