3.1.9.8

ethernetip

Description
With this command, you set whether EtherNet/IP will be enabled or disabled after the next
device restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ethernetip {off|on}
The parameters have the following meaning:
Parameter
off
on
Result
EtherNet/IP is enabled or disabled after the next restart.
Further notes
You can display the current EtherNet/IP configuration with the show ethernetip command.
You restore the default settings of the EtherNet/IP profile with the restart command.
3.1.9.9

pnio

Description
With this command, you configure the setting for PROFINET after the next restart of the device.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
EtherNet/IP will be disa‐
bled after the next restart.
EtherNet/IP will be ena‐
bled after the next restart.
Range of values / note
-
● When EtherNet/IP is turned on, PROFINET is turned off.
The switchover from EtherNet/IP and PROFINET has no
effect on DCP.
● If a PROFINET connection is established; in other words
the PROFINET AR status is "Online", you cannot enable
EtherNet/IP.