Ntp Server - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

5.2.3.1

ntp server

Description
With this command, you configure the connection to a server on the NTP client.
Note
To avoid time jumps, make sure that there is only one time server in the network.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server ipv4 <ip_addr>[port<1025-36564>][poll<seconds(64-1024)>]
The parameter has the following meaning:
Parameter
ipv4
ip_addr
port
poll
seconds
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Keyword for an IPv4 address
Value for the IPv4 address of the time server
UDP port of the time server
Keyword for the time after which the time of day is re‐
quested again
Value for the time in seconds
System time
5.2 NTP client
Range of values / note
-
Enter a valid IPv4 address
1025 ... 36564
-
64 ... 1024