Signaling Contact Mode; Signaling-Contact Status - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Functions specific to SCALANCE
4.4 Signaling contact
4.4.2.1

signaling contact mode

Description
With this command, you specify the reaction of the signaling contact.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
signaling-contact mode {conventional | aligned}
The parameters have the following meaning:
Parameter
conventional
aligned
Result
The reaction of the signaling contact is specified.
Further notes
You display the setting with the show signaling contact command.
4.4.2.2

signaling-contact status

Description
With this command, you close or open the signaling contact.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
140
Description
An error/fault is displayed by the fault LED and the signaling contact is
opened. When the error/fault state no longer exists, the fault LED goes off
and the signaling contact is closed.
The way the signaling contact works does not depend on the error/fault that
has occurred. The signaling contact can be opened or closed as required by
user actions.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06