Siemens SCALANCE XC-200 Configuration Manual page 572

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Diagnostics
12.2 FMP
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
fmp rx-power [req { <integer(0-0)> | - <integer(1-40)>}] [dem
{ <integer(0-0)> | - <integer(1-40)>}]
The parameters have the following meaning:
Parameter
req
dem
Result
The limits for monitoring the received power are defined.
Further notes
You enable this function with the fmp command.
You disable this function with the no fmp command.
You display the status of this function and other information with the and show fmp limit
commands.
You define the limit values for the power loss with the command fmp power-loss.
572
Description
Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Warning"
Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Critical"
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
Configuration Manual, 07/2017, C79000-G8976-C361-06