Shutdown; No Shutdown - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Configuration
3.1 System
3.1.10.14

shutdown

Description
With this command, you shut down the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
shutdown [complete]
The parameter has the following meaning:
Parameter
without parame‐
ters
complete
Result
The Interface is shut down.
If you execute this command without parameters, a connection remains displayed. The LED
for the port status flashes. However no data is sent or received.
Further notes
You activate the interface with the no shutdown command.
You can display the status of this function and other information with the show
interfacescommand.
3.1.10.15

no shutdown

Description
With this command, you shut down an interface.
86
Description
The interface is disabled but the connection remains.
The interface is disabled and the connection to the part‐
ner device is terminated.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
-
For every optical port that
you disable with the
shutdown complete
command, the current con‐
sumtion of the device is re‐
duced by 30 mA.
Configuration Manual, 07/2017, C79000-G8976-C361-06