The parameters have the following meaning:
Parameter
L1
L2
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the power command.
12.1.8.10

link

Description
With this command, you configure and enable the monitoring of the physical network
connections for cable breaks or for pulling of the connector.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
link {up|down}[{<interface-type><interface-id>}]
The parameters have the following meaning:
Parameter
up
down
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
No monitoring of power supply 1
No monitoring of power supply 2
Description
Only the establishment of a connection
is signaled
Only a break on a connection is signaled -
Type or speed of the interface
Module no. and port no. of the interface
Diagnostics
12.1 Event and fault handling
Range of values / note
-
Enter a valid interface.
563