Loopd {Tx-Interval | Detect-Threshold | Reaction-Timeout - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Diagnostics
12.6 Loop detection
The parameters have the following meaning:
Parameter
blocked
forwarder
sender
If you do not select any parameters from the parameter list, the default value is used.
Result
It has been configured how the port handles loop detection frames.
Further notes
You can display the status of this function and other information with the show loopd
command.
12.6.3.2

loopd {tx-interval | detect-threshold | reaction-timeout}

Description
With this command you configure the send interval, threshold value and reaction time for loop
detection.
Requirement
● Loop detection is enabled
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
loopd {tx-interval <mSec(500-5000)> | detect-threshold
<integer(1-500)> | reaction-timeout <seconds(0-86400)>}
The parameters have the following meaning:
Parameter
tx-interval
mSec
604
Description
The forwarding of loop detection frames
is blocked.
Loop detection frames from other devi‐
ces are forwarded.
Loop detection frames are sent out and
forwarded.
Description
Keyword for the send interval
Specifies the send interval for loop de‐
tection frames in milliseconds.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
-
Default after enabling loop detec‐
tion.
-
Range of values / note
-
500 ... 5000
Default: 1000
Configuration Manual, 07/2017, C79000-G8976-C361-06