Passive-Listening Bpdu-Vlan-Flood; No Passive-Listening Bpdu-Vlan-Flood - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Network structures
6.4 Passive Listening
6.4.2.1

passive-listening bpdu-vlan-flood

Description
With this command you enable forwarding of BPDUs for specific VLANs; in other words to all
ports that are members of a VLAN.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
passive-listening bpdu-vlan-flood
As default the function is "enabled".
Result
BPDUs for specific VLANs.
Further notes
You disable this function with the no passive-listening bpdu-vlan-flood command.
You display the status of "passive listening" with the show passive-listening command.
6.4.2.2

no passive-listening bpdu-vlan-flood

Description
With this command you enable the flooding of BPDUs to all available ports of the device
regardless of the configured VLANs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#