Loopd Reaction Local; No Loopd Reaction Local - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

12.6.3.5

loopd reaction local

Description
With this command, you activate the "disable" reaction for a local loop. If a local loop is
detected, the port is blocked.
Requirement
● Loop detection is enabled.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
loopd reaction local
Result
"disable" is activated for the loopd reaction local function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the no loopd reaction local command.
You can display the status of this function and other information with the show loopd
command.
See also
Addresses and interface names (Page 36)
12.6.3.6

no loopd reaction local

Description
With this command, you enable the "no action" reaction for a local loop. If a local loop is
detected, this has no effect on the port.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Diagnostics
12.6 Loop detection
607