Network structures
6.3 Spanning Tree
Syntax
Call up the command with the following parameters:
spanning-tree[mst <instance-id(1-64)>] priority <value(0-61440)>
The parameters have the following meaning:
Parameter
mst
instance-id
priority
value
You can only change the value for the priority in the steps of 4096.
Result
The priority of the device is configured.
Further notes
You can reset the setting to the default with the no spanning-tree priority command.
You display this setting and other information with the commands that start with show
spanning-tree ....
6.3.4.11

no spanning-tree priority

Description
With this command, you reset the priority of the device back to the default value.
The default value is 32768.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree[mst <instance-id(1-64)>]priority
236
Description
Keyword for a Multiple Spanning Tree
instance
Number of the instance
Keyword for the priority
Value for the priority
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
-
1 ... 64
-
0 ... 61440
Default: 32768