The parameters have the following meaning:
Parameter
low
high
critical
If the power of the connected power supply is inadequate to supply all connected devices,
devices with a higher priority are given preference.
If the same priority is set for two ports, the port with the lower number will be preferred when
necessary.
Result
The priority of the corresponding interface has been specified.
3.5.3.10

no poe prio

Description
With this command, you set the priority of an interface to the default value "low".
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe prio
Result
The priority of the corresponding interface has been set to "low".