Parameter
authentication-
failure
rmon-alarm
power-change
rm-state-change
standby-state-
change
faultstate-change
stp-change
vrrp-state-change
loopd-state-
change
ospf-state-change
dot1x-port-auth-
state-change
poe-state-change
fmp-state-change
all
logtable
syslog
email
trap
faults
env-data-change
linkcheck-change
cli-script-file-
status
all
Result
The setting deciding which messages of the device are not stored or forwarded is configured.
Further notes
You display the status of the events and the clients with the show events config command.
You configure which of the various message types of the device will be stored or forwarded
with the event config command.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Message if there is an incorrect login
Message when there is a RMON alarm
Message when there is a status change in the power supply
Message when there is a status change in the redundancy manager
Message when there is a status change on a standby connection
Message when there is a status change in the error monitoring
Message when there is a change in the spanning tree
Message on status change of VRRP routers
Message if there is a status change in the detection of network loops
Message on status change of OSPF
Message when there is a status change in the 802.1X authentication
Message on status change of PoE
Message on status change of FMP
All messages
Client that processes the logbook entries
Client that sends the messages to the Syslog server
Client that sends the e-mails
Client that sends the SNMP traps
Error LED lights up. The setting is possible only for a cold or warm restart.
Message when there is a status change in the diagnostics data
Message on status change of Link Check
Message when an error was detected in the CLI script file:
All clients at once
Diagnostics
12.1 Event and fault handling