No Switchport Priority Default; Switchport Private-Vlan Host-Association - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

6.1.3.11

no switchport priority default

Description
With this command, you reset the priority default for the interface to the default value.
The default value is 0.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport priority default
Result
The setting is reset to the default value.
Further notes
You configure the priority default with the switchport priority default command.
You display this setting and other information with the show vlan port config command.
6.1.3.12

switchport private-vlan host-association

Description
With this command, you configure a host port.
The following settings are made:
● The interface becomes an untagged member of the primary PVLAN and its secondary
PVLANs.
● With incoming untagged frames, the port VLAN-ID of the secondary VLAN is set.
● Ingress filtering is enabled.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Network structures
6.1 VLAN
187