Syntax
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
Parameter
full
half
Result
The duplex mode of the interface is configured.
Further notes
You can reset the duplex mode of the Interface to the default value with the no duplex
command.
You disable autonegotiation with the no negotiation command.
3.1.10.6

no duplex

Description
With this command, you reset the duplex mode of an interface to the default value.
The default value is full.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no duplex
Result
The duplex mode of the Interface is reset to the default value.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
The Interface will be operated in full du‐
plex mode.
The Interface will be operated in half du‐
plex mode
Configuration
3.1 System
Range of values / note
Default: full
-
79

Hide quick links:

Advertisement