Siemens SCALANCE XC-200 Configuration Manual page 344

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Network protocols
7.5 SNMP
Syntax
Call up the command with the following parameters:
snmp targetparams <ParamName>
The parameters have the following meaning:
Parameter
ParamName
user
UserName
security-model
message-
processing
Keywords need to be specified.
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.
344
user <UserName>
security-model {v1|v2c|v3 {auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
Description
Name of the SNMP parameter
Keyword for the user name
Value for the user name
Specifies which SNMP version is used.
With SNMPv3 a security level (authen‐
tication, encryption) can also be config‐
ured.
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
max. 32 characters
-
max. 32 characters
● SNMP version
v1
v2c
v3
● Security level for v3
auth
Authentication enabled / no
encryption enabled
noauth
No authentication enabled,
no encryption enabled
priv
Authentication enabled /
encryption enabled
● SNMP version
v1
v2c
v3
● Settings after the restart
:
The settings are lost after a
restart
:
The settings are retained
after a restart