No Instance - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Network structures
6.3 Spanning Tree
Syntax
Call up the command with the following parameters:
instance <instance-id(1-64)> vlan <vlan-range>
The parameters have the following meaning:
Parameter
instance-id
vlan
vlan-range
Result
The range of VLANs is assigned to the MST instance.
Further notes
You cancel the assignment of the VLAN to an MST instance with the no instance command.
You delete the MST instance with the no instance command.
You display this setting and other information with the show spanning-tree mst
configuration command.
6.3.6.2

no instance

Description
With this command, you cancel the assignment of a VLAN to an MST instance or delete the
MST instance.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call up the command with the following parameters:
260
Description
Number of the instance
Keyword for a VLAN connection
Range of VLANs assigned to an in‐
stance
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
1 ... 64
You can define up to 16 MSTP in‐
stances.
Default:
The VLANs 1 ... 4094 are assigned
to instance "0"
-
1 ... 4094
Enter the range limits with a hy‐
phen without a space.
Configuration Manual, 07/2017, C79000-G8976-C361-06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents