Diagnostics
12.3 Syslog client
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
● If you exit the EVENTS configuration mode with the exit command, you return to the
Global configuration mode.
● If you exit the EVENTS configuration mode with the end command, you return to the
Privileged EXEC mode.
12.3.2.1

syslogserver

Description
With this command, you configure the Syslog server address.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 <ucast_addr>} [<port(1-65535)>]
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
port
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured.
Further notes
You disable the setting with the no syslogserver command.
You can display the status of this function and other information with the show events
config command.
574
Description
Keyword for an IP address
Syslog server IPv4 address
Serverport
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
-
Enter a valid IPv4 address.
1 .. 65535
Default: 514