SIMATIC NET
Industrial Ethernet switches
SCALANCE XR-300WG
Operating Instructions
03/2021
C79000-G8976-C454-07
Introduction
Safety notices
Recommendations on
network security
Description of the device
Installation
Connecting up
Upkeep and maintenance
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE XR-300WG

  • Page 1 Introduction Safety notices Recommendations on network security SIMATIC NET Description of the device Industrial Ethernet switches SCALANCE XR-300WG Installation Connecting up Operating Instructions Upkeep and maintenance Technical specifications Dimension drawings Approvals 03/2021 C79000-G8976-C454-07...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................5 Safety notices ............................9 Recommendations on network security ....................11 Description of the device ........................17 Product overview ....................... 17 Device views ........................21 4.2.1 Device view of a 24 VDC variant ..................21 4.2.2 Device view of 240 VAC variant ..................
  • Page 4 Table of contents Wiring rules ........................54 24 VDC power supply......................55 Power supply 240 VAC ....................... 57 PoE power supply (power expansion) ................. 59 Serial interface........................63 Functional ground ......................65 Protective grounding (PoE variants) ..................67 Upkeep and maintenance........................69 Downloading new firmware using TFTP without WBM and CLI..........
  • Page 5: Introduction

    Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting up devices of the SCALANCE XR-300WG product group. The configuration and the integration of the devices in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: •...
  • Page 6 You will find the supplementary documentation here: • On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection • On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15247) Documentation on configuration...
  • Page 7 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 8 Introduction Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
  • Page 9: Safety Notices

    Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 10 Safety notices SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 11: Recommendations On Network Security

    Industrial Security (https://www.siemens.com/ industrialsecurity) website. • Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). • Only activate protocols that you require to use the device. • Restrict access to the management of the device with rules in an access control list (ACL).
  • Page 12 Recommendations on network security • The option of VLAN structuring provides protection against DoS attacks and unauthorized access. Check whether this is practical or useful in your environment. • Use a central logging server to log changes and accesses. Operate your logging server within the protected network area and check the logging information regularly.
  • Page 13 Recommendations on network security Secure/non-secure protocols and services • Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non-secure protocols on the device with caution. •...
  • Page 14 Recommendations on network security Available protocols The following list provides you with an overview of the open protocol ports. The table includes the following columns: • Protocol • Port • Default port status – Open The factory setting of the port is "Open". –...
  • Page 15 Recommendations on network security Protocol Protocol/ Default port sta‐ Configurable Authentication Encryption Port number port PROFINET UDP/34964 Open ✓ UDP/49151 … 49159 RADIUS UPD/1812,1813 Closed ✓ SMTP TCP/25 Closed ✓ TCP/465 SNMP UDP/161 Open ✓ Yes (when con‐ figured) TCP/22 Open ✓...
  • Page 16 Recommendations on network security SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 17: Description Of The Device

    Description of the device Product overview Article numbers Device Properties Article number SCALANCE 24 V DC variant 6GK5 324-0BA00-2AR3 XR324WG • 24 x 10/100 Mbps RJ45 ports • 2 x 24 VDC, connector for the power supply on the front •...
  • Page 18 Description of the device 4.1 Product overview Device Properties Article number SCALANCE 24 V DC variant 6GK5 328-4FS00-2AR3 XR328‑4C WG • 24 x 10/100 Mbps RJ45 ports • 4 x combo ports (4 x 10/100/1000 Mbps RJ45 ports/4 x pluggable transceiver slots with 1000 Mbps) •...
  • Page 19 Description of the device 4.1 Product overview Factory settings: Industrial Ethernet profile • Industrial Ethernet protocol: PROFINET • Base Bridge Mode: 802.1Q VLAN Bridge • Redundancy mechanism: RSTP • Trust mode: Trust CoS-DSCP • IGMP Snooping/IGMP Querier: Off • IPv4 Address Collision Detection: Never give up Type designation The type designation of a SCALANCE XR-300WG is made up of several parts that have the following meaning:...
  • Page 20 Description of the device 4.1 Product overview Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use damaged parts, this can lead to the following problems: •...
  • Page 21: Device Views

    Description of the device 4.2 Device views Device views 4.2.1 Device view of a 24 VDC variant The following figure shows an overview of the components of a 24 VDC variant of a SCALANCE XR‑300WG based on the example of a SCALANCE XR328‑4C WG. ①...
  • Page 22: Device View Of 240 Vac Variant

    Description of the device 4.2 Device views 4.2.2 Device view of 240 VAC variant The following figure shows an overview of the components of a 240 VAC variant of a SCALANCE XR‑300WG based on the example of a SCALANCE XR328‑4C WG. ①...
  • Page 23: Device View Of A Poe Variant

    Description of the device 4.2 Device views 4.2.3 Device view of a PoE variant The following figure provides an overview of the components of a PoE variant of a SCALANCE XR 300WG using the example of a SCALANCE XR326-2C PoE WG. ①...
  • Page 24: Accessories

    Description of the device 4.3 Accessories Accessories The following accessories are available for SCALANCE XR-300WG: Cable Component Description Article number Connecting ca‐ Preassembled, serial cable with RJ-11 and RS-232 plug, 6GK5 980-3BB00-0AA5 Length: 3 m (RJ-11/RS-232) pack of 1 Power cable Type Description Article number...
  • Page 25 Description of the device 4.3 Accessories Note Active plug-in transceivers can be used with the following devices: • SCALANCE XR328-4C WG Pluggable transceiver SFP (1000 Mbps) Type Property Article number SFP992-1 1 x 1000 Mbps, LC port optical for glass FO cable 6GK5 992-1AL00-8AA0 (multimode), up to max.
  • Page 26 Description of the device 4.3 Accessories Bidirectional plug-in transceiver SFP Bidirectional plug-in transceivers feature only one fiber connection. They transmit and receive on two different wavelengths. To establish a connection, you need two matching bidirectional SFPs. The connected SFPs must respectively transmit on the wavelength at which the connection partner receives.
  • Page 27: Led Display

    Description of the device 4.4 LED display LED display 4.4.1 Fault LED "F" The fault LED "F" indicates the incorrect functioning of the device. LED color LED status Meaning The device is switched off or has not detected a problem. The device has detected a problem.
  • Page 28 Description of the device 4.4 LED display The upper green LED shows the status of the link. LED color LED status Meaning Green link exists No link exists The lower yellow LED shows the status of data reception. LED color LED status Meaning Yellow...
  • Page 29: Reset Button

    Description of the device 4.5 RESET button RESET button WARNING EXPLOSION HAZARD Do not press the RESET button if there is a potentially explosive atmosphere. Position The "RESET" button is located on the front of the SCALANCE XR-300WG. Figure 4-1 Position of the "RESET"...
  • Page 30 Description of the device 4.5 RESET button Procedure To reset the device to the factory defaults during operation, follow the steps below: 1. Press the "RESET" button. 2. Hold down the button for approximately 12 seconds. After 9 seconds, the fault LED "F" flashes for 3 seconds. –...
  • Page 31: Combo Ports

    Description of the device 4.6 Combo ports Combo ports Characteristics Combo port is the name for two communication ports. A combo port has the two following jacks: • a fixed RJ-45 port • an SFP transceiver slot that can be equipped individually Of these two ports, only one can ever be active.
  • Page 32: Power Over Ethernet

    Description of the device 4.7 Power over Ethernet Power over Ethernet Function The "Power over Ethernet" function supplies connected devices with power via the Ethernet cable. Devices supplied with power via an Ethernet cable do not require a separate voltage source.
  • Page 33: Power Transfer And Pin Assignment (Ports P1 - P24)

    Description of the device 4.7 Power over Ethernet Power source • The device can supply energy consumers of the standards IEEE802.af Type 1, IEEE802.at Type 2 or IEEE802.3bt Type 3. • A power source can make provide a total of 210 W available (including line losses). The power can be distributed to the ports as desired.
  • Page 34: Power Transfer And Pin Assignment (Ports P25 And P26)

    Description of the device 4.7 Power over Ethernet 4.7.4 Power transfer and pin assignment (ports P25 and P26) The table below shows the most important power transfer and pin assignment for ports P25 and P26. Pin number Assignment Pin 1 Negative power supply Pin 2 Negative power supply...
  • Page 35: Installation

    Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 40 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 40 ℃.
  • Page 36 Installation 5.1 Safety notices for installation WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
  • Page 37 Installation 5.1 Safety notices for installation WARNING Do not remove or replace while circuit is live when a flammable or combustible atmosphere is present. WARNING Explosion hazard Do not disconnect equipment when a flammable or combustible atmosphere is present. WARNING EXPLOSION HAZARD For operation the device is intended to be installed within an enclosure/control cabinet.
  • Page 38 Installation 5.1 Safety notices for installation Additional notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility.
  • Page 39: Types Of Installation

    Installation 5.2 Types of installation Types of installation The devices can be installed in the following ways: • 19" rack mounting • DIN rail • Wall mounting Installation position for PoE variants Horizontal installation position is recommended for PoE variants (inscription is in the read direction).
  • Page 40: 19" Rack Mounting

    Installation 5.3 19" rack mounting 19" rack mounting Mounting CAUTION Risk of injury if subjected to irregular mechanical strain The device must be mounted in the 19" rack so that even if there is irregular mechanical strain, no dangerous situation can result. Figure 5-1 19"...
  • Page 41 Installation 5.3 19" rack mounting NOTICE Rack-mount instructions A) Elevated Operating Ambient - If installed in a closed or multi-unit rack, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
  • Page 42: Din Rail Mounting / Wall Mounting

    Installation 5.4 DIN rail mounting / wall mounting DIN rail mounting / wall mounting Installation DIN rail mounting and wall mounting are described in this section, because a DIN rail is required also for wall mounting. Note that PoE variants have a different guide rail. SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 43 Installation 5.4 DIN rail mounting / wall mounting Follow these steps to install the device with a DIN rail: 1. In the recess on the top of the housing, there are two guides for receiving a DIN rail. Push the DIN rail into the guides as shown in the following figure: Figure 5-2 Connecting SCALANCE and DIN rail...
  • Page 44 Installation 5.4 DIN rail mounting / wall mounting Figure 5-3 Assembling PoE variants and standard mounting rail 2. Screw the protruding ends of the DIN rail to the wall or other surface for attaching the DIN rail. Screwing in the DIN rail Screwing on the standard mounting rail for PoE variants 3.
  • Page 45 Installation 5.4 DIN rail mounting / wall mounting Uninstalling To uninstall the device, follow the steps below: 1. Remove all connected cables. 2. Loosen the screws of the DIN rail. 3. Take the DIN rail out of the housing. SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 46: Inserting And Removing Pluggable Transceivers

    WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
  • Page 47: Removing A Pluggable Transceiver (Sfp)

    Installation 5.5 Inserting and removing pluggable transceivers 5.5.3 Removing a pluggable transceiver (SFP) Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver to cool down as much as possible.
  • Page 48 Installation 5.5 Inserting and removing pluggable transceivers SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 49: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. If using power sources according to NEC Class 2 or LPS, please note the following information: WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 50 Connecting up 6.1 Safety when connecting up Safety notices when using the device according to Hazardous Locations (HazLoc) and FM. If you use the device under HazLoc or FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING EXPLOSION HAZARD You may only connect or disconnect cables carrying electricity when the power supply is...
  • Page 51: Industrial Ethernet

    Connecting up 6.2 Industrial Ethernet Industrial Ethernet 6.2.1 Electrical Note Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar. R-45 connector technology The attachment to Industrial Ethernet uses RJ-45 connected technology with MDI-X assignment.
  • Page 52 Connecting up 6.2 Industrial Ethernet MDI / MDI-X autocrossover With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically. The assignment depends on the cable with which the communications partner is connected. This means that it does not matter whether the port is connected using a patch cable or crossover cable.
  • Page 53: Optical

    Connecting up 6.2 Industrial Ethernet 6.2.2 Optical NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Take the following precautions to avoid functional impairments: •...
  • Page 54: Wiring Rules

    Connecting up 6.3 Wiring rules Wiring rules When wiring, use cables with the following AWG* categories or cross sections. Wiring rules for ... Spring-loaded terminals connectable cable cross sec‐ without wire end ferrule 0.75 - 2.5 mm tions for flexible cables ... AWG: 20 - 14 with wire end ferrule** 0.75 - 2.5 mm...
  • Page 55: Vdc Power Supply

    Connecting up 6.4 24 VDC power supply 24 VDC power supply Safety extra low voltage WARNING Power supply The device is designed for operation with a directly connectable safety extra-low voltage (SELV). NOTICE Suitable fusing for the power supply cables The current on the terminal may not exceed 5 A.
  • Page 56 Connecting up 6.4 24 VDC power supply CAUTION Overvoltage protection for the power supply cables If SCALANCE XR-300WGs are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines. These can result, for example, due to lightning or switching of large inductive loads.
  • Page 57: Power Supply 240 Vac

    Connecting up 6.5 Power supply 240 VAC Power supply 240 VAC Notes on the power supply WARNING Danger from line voltage for devices with a 240 VAC power supply This device can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended.
  • Page 58 Connecting up 6.5 Power supply 240 VAC Position Figure 6-2 Position of the device installation connector Figure 6-3 Position of the device installation connector in PoE variants SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 59: Poe Power Supply (Power Expansion)

    Connecting up 6.6 PoE power supply (power expansion) PoE power supply (power expansion) Notes on the PoE power supply WARNING Danger from line voltage for devices with a 240 VAC power supply This device can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended.
  • Page 60 Connecting up 6.6 PoE power supply (power expansion) Note Use in IT networks When used in IT networks, the power supply 240 VAC also applies to the connected IT network: Phase-to-phase. Information on the PoE power supply • The total available PoE power of the SCALANCE XR326-2C PoE WG can be expanded using up to two additional SCALANCE PSR9230PoE power supplies.
  • Page 61 Connecting up 6.6 PoE power supply (power expansion) Power cables for SCALANCE XR326-2C PoE WG To connect a SCALANCE PSR9230PoE PoE power supply, use the preassembled power cable ① supplied ① To connect two SCALANCE PSR9230PoE, you need two power cables .
  • Page 62 Connecting up 6.6 PoE power supply (power expansion) Documentation You can find detailed information on the SCALANCE PSR9230PoE PoE power supply in the corresponding operating instructions, see the section "Introduction (Page 5)", "Additional documentation". SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 63: Serial Interface

    Connecting up 6.7 Serial interface Serial interface Information on the serial interface • Via the serial interface (RJ-11 jack), you can access the CLI of the device directly via an RS-232 connection (115200 8N1) without assigning an IP address. • Access to the device is also possible independent of the Ethernet ports. •...
  • Page 64 Connecting up 6.7 Serial interface Note Pin assignment of the RJ-11 jack on the device The RJ-11 jack on the device has a pinout to match the RJ-11 plug of the connecting cable mentioned above. SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 65: Functional Ground

    Connecting up 6.8 Functional ground Functional ground Grounding options Grounding (functional grounding) takes place via the mounting bracket on the device or via the grounding screw at the front of the device. Figure 6-7 Position of the grounding screw on the front of the device. With 240 VAC variants the device is grounded via the power cable.
  • Page 66 Connecting up 6.8 Functional ground To connect the functional grounding for devices with a grounding screw, proceed as follows: 1. Loosen the grounding screw. ① ② 2. Put the grounding terminal , and the grounding screw together as shown in the drawing.
  • Page 67: Protective Grounding (Poe Variants)

    Connecting up 6.9 Protective grounding (PoE variants) Protective grounding (PoE variants) Grounding options For PoE variants, grounding (protective grounding) takes place using the grounding bolts on the rear of the device. Figure 6-8 Position of the grounding bolt on the back of the device for PoE variants Protective grounding The connection of the reference potential surface with the protective conductor system is normally in the control cabinet close to the power feed-in.
  • Page 68 Connecting up 6.9 Protective grounding (PoE variants) To connect the functional grounding for devices with a grounding bolt, proceed as follows: ① ② ③ 1. Put the parts together on the grounding bolt as shown in the drawing. ④ 2. Tighten the nut with a maximum tightening torque of 1.5 Nm.
  • Page 69: Upkeep And Maintenance

    Upkeep and maintenance Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows You can download new firmware to the device using TFTP. To do this, the device does not need to be reachable either using Web Based Management (WBM) or using the Command Line Interface (CLI).
  • Page 70: Restoring The Factory Settings

    Upkeep and maintenance 7.2 Restoring the factory settings Restoring the factory settings NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network. With the "RESET"...
  • Page 71: Technical Specifications

    Technical specifications Technical specifications of the SCALANCE XR324WG 8.1.1 24 VDC variant The following technical specifications apply to the 24 VDC variant of the SCALANCE XR324WG. Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps Diagnostics interface...
  • Page 72 Technical specifications 8.1 Technical specifications of the SCALANCE XR324WG Technical specifications Installation options • 19" rack mounting • DIN rail • Wall mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 56 years SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 73: Vac Variant

    Technical specifications 8.1 Technical specifications of the SCALANCE XR324WG 8.1.2 240 VAC variant The following technical specifications apply to the 240 VAC variant of the SCALANCE XR324WG. Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed 10 / 100 Mbps...
  • Page 74: Technical Specifications Of Scalance Xr326-2C Poe Wg

    Technical specifications 8.2 Technical specifications of SCALANCE XR326-2C PoE WG Technical specifications of SCALANCE XR326-2C PoE WG The following technical specifications apply to the SCALANCE XR326-2C PoE WG. Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed...
  • Page 75 Technical specifications 8.2 Technical specifications of SCALANCE XR326-2C PoE WG Technical specifications Weight 4700 g Installation options • 19" rack mounting • DIN rail • Wall mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 25 years SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 76: Technical Specifications Of The Scalance Xr328-4C Wg

    Technical specifications 8.3 Technical specifications of the SCALANCE XR328-4C WG Technical specifications of the SCALANCE XR328-4C WG 8.3.1 24 VDC variant The following technical specifications apply to the 24 VDC variant of the SCALANCE XR328-4C Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector...
  • Page 77 Technical specifications 8.3 Technical specifications of the SCALANCE XR328-4C WG Technical specifications Housing material Metal Degree of protection IP30 Dimensions (W x H x D) 482.6 x 43.6 x 127 mm Weight 2800 g Installation options • 19" rack mounting •...
  • Page 78: Vac Variant

    Technical specifications 8.3 Technical specifications of the SCALANCE XR328-4C WG 8.3.2 240 VAC variant The following technical specifications apply to the 240 VAC variant of the SCALANCE XR328-4C Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties Half/full duplex, MDI‑X pinning Transmission speed...
  • Page 79 Technical specifications 8.3 Technical specifications of the SCALANCE XR328-4C WG Technical specifications Installation options • 19" rack mounting • DIN rail • Wall mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 39 years Depending on which pluggable transceiver you use, the maximum ambient temperature can change, see section "Accessories (Page 24)".
  • Page 80: Technical Specifications Of The Scalance Xr328-4C Wg (Ge)

    Technical specifications 8.4 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications of the SCALANCE XR328-4C WG (GE) 8.4.1 24 VDC variant The following technical specifications apply to the 24 VDC variant of the SCALANCE XR328-4C WG (GE). Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity...
  • Page 81 Technical specifications 8.4 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications Housing material Metal Degree of protection IP30 Dimensions (W x H x D) 482.6 x 43.6 x 127 mm Weight 2800 g Installation options • 19" rack mounting •...
  • Page 82: Vac Variant

    Technical specifications 8.4 Technical specifications of the SCALANCE XR328-4C WG (GE) 8.4.2 240 VAC variant The following technical specifications apply to the 240 VAC variant of the SCALANCE XR328-4C WG (GE). Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties...
  • Page 83 Technical specifications 8.4 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications Installation options • 19" rack mounting • DIN rail • Wall mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 31 years SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 84: Mechanical Stability (In Operation)

    Technical specifications 8.5 Mechanical stability (in operation) Mechanical stability (in operation) The following technical specifications apply to SCALANCE XR-300WG. IEC 60068-2-27 shock IEC 60068-2-6 vibration 15 g, 11 ms duration 10 - 58 Hz: 0.075 mm 6 shocks per axis 85 - 150 Hz: 1 g 1 octave/min, 20 sweeps SCALANCE XR-300WG...
  • Page 85: Cable Lengths

    Technical specifications 8.6 Cable lengths Cable lengths The cable lengths listed below apply to the SCALANCE XR-300WG. Cable Permitted cable length IE TP torsion cable 0 to 45 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE TP torsion cable 0 to 55 m with IE FC RJ-45 Plug 180...
  • Page 86: Switching Properties

    Technical specifications 8.7 Switching properties Switching properties The switching properties listed below apply to the SCALANCE XR-300WG. Switching properties Aging time Can be configured (default value: 30 seconds) Maximum frame size 2048 Max. number of learnable address‐ 16382 Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding...
  • Page 87: Dimension Drawings

    Dimension drawings Note Dimensions are specified in mm. Front view of the SCALANCE XR-300WG Figure 9-1 Width and height based on the example of a 24 V DC variant SCALANCE XR-300WG 24 VDC variant view from above Figure 9-2 Depth SCALANCE XR-300WG 240 VAC variant view from above Figure 9-3 Depth...
  • Page 88 Dimension drawings SCALANCE XR-300WG PoE variant view from above Figure 9-4 Depth SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 89: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 90 EC L174, 01/07/2011, p. 88-110 You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/ cert).
  • Page 91 • On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection • On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially Explosive...
  • Page 92 Approvals Permitted types of protection The following types of protection are possible: • nA ATEX classification: II 3 G Ex nA IIC T4 Gc Certificate no.: KEMA 07ATEX0145 X The products meet the requirements of the following standards: – EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 93 Approvals The following types of protection are possible: • nA IECEx classification: Ex nA IIC T4 Gc Certificate no.: DEK 14.0025X The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 94 Approvals Safety of electrical equipment (Low Voltage Directive) The SIMATIC NET products described in these operating instructions meet the requirements of EU directive 2014/35/EU "Low Voltage Directive". Applied standard: • EN 60950-1 Information technology equipment - Safety - Part 1: General requirements Note Only variants with 100 to 240 V AC power supply meet the requirements of this approval.
  • Page 95 Approvals cULus approval for industrial control equipment cULus Listed IND. CONT. EQ. Underwriters Laboratories Inc. complying with • UL 61010-2-201 • CAN/CSA-IEC 61010-2-201 Report no. E85972 cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. according to either •...
  • Page 96 Approvals Applied standards: • AS/NZS CISPR11 (Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement). • EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid RCM SDoCs (Self- Declaration of Conformity).
  • Page 97 • "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) • "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) • "EMC Installation Guidelines" configuration manual (https:// support.industry.siemens.com/cs/ww/en/view/60612658)
  • Page 98 Approvals SCALANCE XR-300WG Operating Instructions, 03/2021, C79000-G8976-C454-07...
  • Page 99: Index

    Index 19" rack mounting, 21, 22, 23, 40 Glossary, 7 Grounding screw, 21, 22, 23, 66 Approvals, 89 Article number, 17 Housing, 71, 73, 74, 76, 78, 80, 82 Autonegotiation, 52 AWG, 54 Installation, 71, 73, 74, 76, 78, 80, 82 Installation on a DIN rail, 42 Bracket, 21, 22, 23, 40, 65 LED display...
  • Page 100 Index SFP, 5, 25 SFP active, 24 Pluggable transceiver slot, 46, 47 Plug-in transceiver SFP bidirectional, 26 PoE, 32 Port LED, 21, 22, 23, 27, 28 Power cable, 24, 57, 60, 65 Power over Ethernet, 32 Power supply, 71, 73, 74, 76, 78, 80, 82 230 VAC, 17, (Power cable) 24 VDC, 17, 21, 56 240 VAC, 22, 23, (Power cable)