Ring-Redundancy Hrpobserver - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

The command prompt is as follows:
cli(config-red)#
Further notes
You exit the Redundancy Configuration mode with the end or exit command.
8.4.5.2

ring-redundancy hrpobserver

Description
With this command, you enable the observer or restart it.
The "observer" function is only available in HRP rings. The observer monitors malfunctions of
the redundancy manager or incorrect configurations of an HRP ring.
If the observer is enabled, it can interrupt the connected ring if errors are detected. To do this,
the observer switches a ring port to the "blocking" status. When the error is resolved, the
observer enables the port again.
If numerous errors occur in quick succession, the observer no longer enables its port
automatically. The ring port remains permanently in the "blocking" status. This is signaled by
the error LED and a message text. After the errors have been eliminated, you can enable the
port again with this command and the parameter restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ring-redundancy hrpobserver [restart]
The parameters have the following meaning:
Parameter
restart
If you do not specify the optional parameter, the observer is enabled.
Result
The observer is enabled or restarted.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Restarts the observer.