Network protocols
7.5 SNMP
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|
none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
GroupName
Version
Authentication
read
write
notify
Storage Type
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
332
Description
Name of the group to which access is
configured
Selects the version of the protocol used ● v1
Selects the authentication method.
The data can be read.
Keyword
The data can be read and written
Keyword
Changes can be sent as a tag.
Keyword
Specifies whether the settings remain
following a restart.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Range of values / note
max. 32 characters
● v2c
● v3
● auth
Enables MD5 or SHA as
authentication method
● noauth
No authentication
● priv
Enables authentication and
encryption
● ReadView
● none
● WriteView
● none
● NotifyView
● none
● volatile :
The settings are lost after a
restart
● nonvolatile :
The settings are retained after
a restart