The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show loopd
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
Information on loop detection is displayed.
12.6.1.2

show loopd interface

Description
Displays information on the loop interface.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command without parameters or with the following parameter assignment:
show loopd interface [{<interface-type> <interface-id> | port-
channel <port-channel-id (1-8)>}]
The parameters have the following meaning:
Parameter
interface
interface-type
interface-id
port-channel
port-channel-id
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select any parameters from the parameter list, the default value is used.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
Description
Keyword for a an interface description
Type or speed of the interface
Module no. and port no. of the interface
Keyword for a port channel connection
Number of the addressed port channel
Diagnostics
12.6 Loop detection
Range of values / note
-
Enter a valid interface.
-
1 ... 8