Download Print this page

Data Required For Main Positioning Control - Mitsubishi A1SD75M3 User Manual

Positioning module

Advertisement

9 MAIN POSITIONING CONTROL

9.1.1 Data required for main positioning control

Setting item
Operation pattern
Da.1
Control method
Da.2
Acceleration time No.
Da.3
Deceleration time No.
Da.4
Positioning address/
Da.5
movement amount
Arc address
Da.6
Command speed
Da.7
Dwell time
Da.8
M code
Da.9
* The settings and setting requirement for the setting details of
"
Control method". (Refer to section "9.2 Setting the positioning data".)
Da.2
The following table shows an outline of the "positioning data" configuration and setting
details required to carry out the "main positioning controls".
Set the method by which the continuous positioning data (Ex: positioning data No. 1,
No. 2, No. 3) will be controlled. (Refer to section 9.1.2.)
Set the control method defined as a "main positioning control". (Refer to section 9.1.)
Select and set the acceleration time at control start. (Select one of the four values set in
Pr.8 , Pr.26 , Pr.27 , and Pr.28 for the acceleration time.)
Select and set the deceleration time at control stop. (Select one of the four values set in
Pr.9 , Pr.29 , Pr.30 , and Pr.31 for the deceleration time.)
Set the target value during position control. (Refer to section 9.1.3.)
Set the auxiliary point or center point address during circular interpolation control.
Set the speed during the control execution.
Set the time the machine waits from the completion of the executed positioning control
and the stopping of the workpiece until the judgment of the AD75 positioning
completion.
Set this item when carrying out auxiliary work (clamp and drill stops, tool replacement,
etc.) corresponding to the code No. related to the positioning data execution.
Main positioning control auxiliary functions
Refer to section "3.3.4 Combination of AD75 main functions and auxiliary
functions" for details on "auxiliary functions" that can be combined with the main
positioning control.
Also refer to "Chapter 12 CONTROL AUXILIARY FUNCTIONS" for details on each
auxiliary function.
Main positioning control from peripheral devices
"Main positioning control" can be executed from the AD75 software package test
mode.
Refer to the AD75 Software Package Operating Manual for details on carrying out
main positioning control from the AD75 software package.
REMARK
Up to 600 positioning data items (positioning data No.1 to 600) can be set per axis.
Setting details
to
Da.1
9 - 3
MELSEC-A
differ according to the
Da.9

Hide quick links:

Advertisement

loading

This manual is also suitable for:

A1sd75m2A1sd75m1Ad75m2Ad75m1Ad75m3