Summary of Contents for Mitsubishi AJ71PB92D

  • Page 1 PROFIBUS-DP Interface Module Type AJ71PB92D/A1SJ71PB92D User s Manual Mitsubishi Programmable Controller...
  • Page 3 (1) Communication with the slave station is stopped. (2) For the input data received from the slave station, the values at CPU module stop error occurrence are held. (3) For the output data sent from the A1SJ71PB92D/AJ71PB92D to the slave station are cleared.
  • Page 4 [DESIGN PRECAUTIONS] CAUTION • When the PROFIBUS cable is laid, do not lay it close to main circuits or power lines. They should be installed 100mm(3.9inch) or more from each other.Not doing so could result in noise that would cause malfunctioning. [INSTALLATION PRECAUTIONS] CAUTION •...
  • Page 5 [WIRING PRECAUTIONS] CAUTION • Be sure to shut off all phases of the external power supply used by the system before wiring PROFIBUS cables. If you not switch off the external power supply, it will cause failure or malfunction of the module. •...
  • Page 6 [OPERATING PRECAUTIONS] DANGER • Do not write data into the "System area (use prohibited)" of the buffer memory of special function modules. Also, do not output the "Use prohibited" signal as the output signal to a special function module from the PLC CPU.
  • Page 7 Japanese Manual Version SH-3330-H This manual does not imply guarantee or implementation right for industrial ownership or implementation of other rights. Mitsubishi Electric Corporation is not responsible for industrial ownership problems caused by use of the contents of this manual.
  • Page 8 INTRODUCTION Thank you for purchasing the Mitsubishi Programmable Controller MELSEC-A Series. Before using the equipment, plese read this manual carefully to develop full familiarity with the functions and performance of the graphic operation terminal you have purchased, so as to ensure correct use.
  • Page 9 Appendix 1.2 Restrictions on Use of A1SJ71PB92D Software Versions in the Same System ....App- 2 Appendix 1.3 Differences between AJ71PB92D Software Versions ............App- 2 Appendix 1.4 Restrictions on Use of AJ71PB92D Software Versions in the Same System .......App- 2 Appendix 2 When Replacing AJ71PB92 with A1SJ71PB92D/AJ71PB92D ............App- 3 Appendix 2.1 Precautions ..........................App- 3...
  • Page 10 Fax : +49(21 02)486-717 COMPLIANCE WITH THE EMC AND LOW VOLTAGE DIRECTIVES When incorporating the Mitsubishi programmable controller into other machinery or equipment and keeping compliance with the EMC and low voltage directives, refer to Chapter 3 "EMC Directive and Low Voltage Instruction" of the User’s Manual (hardware) supplied with your CPU module or base unit.
  • Page 11 Generic Term/Abbreviation Description of the abbreviation/general terms Abbreviation of the model A1SJ71PB92D, PROFIBUS-DP interface module A1SJ71PB92D/AJ71PB92D Abbreviation of the model AJ71PB92D, PROFIBUS-DP interface module PROFIBUS-DP Abbreviation of PROFIBUS-DP network Generic term for A1SCPUC24-R2, A1SJHCPU, A1SHCPU, A2SHCPU, A1NCPU, A1NCPUP21, A1NCPUP21-S3, A1NCPUR21, A2NCPU, A2NCPUP21, A2NCPUP21-S3, A2NCPUR21, A2NCPU-S1,...
  • Page 12 • Time stamping etc. Class 1 master station A device exchanging I/O data with a slave stations. (A1SJ71PB92D, AJ71PB92D, etc) A device that communicates with slave stations and checks their FDL address settings and/or operation states Class 2 master station The class 2 master station is used as a master station for supervising the network, which can start, maintain, and diagnose the system.
  • Page 13 PRODUCT STRUCTURE The product structure of this product is given in the table below. Model Product Name Quantity A1SJ71PB92D A1SJ71PB92D PROFIBUS-DP interface module AJ71PB92D AJ71PB92D PROFIBUS-DP interface module...
  • Page 14 A1SJ71PB92D or AJ71PB92D accordingly.). When explain separately, which is used to connect a MELSEC-A/QnA/Q series programmable controller to a PROFIBUS-DP network. The A1SJ71PB92D/AJ71PB92D operates as a class 1 master station in the PROFIBUS-DP network. Class 1 master station (A1SJ71PB92D/AJ71PB92D)
  • Page 15 (a) Up to 60 slave stations are connectable Up to 60 slave stations can be connected to a single A1SJ71PB92D/AJ71PB92D, enabling the I/O data exchange of max. 3840 bytes. (Input data: max.1920 bytes, Output data: max.1920 bytes) (Refer to Section 4.1.1)
  • Page 16 2. SYSTEM CONFIGURATION MELSEC-A 2. SYSTEM CONFIGURATION This chapter describes the system configuration of A1SJ71PB92D/AJ71PB92D. Whole System Configuration (1) For the A1SJCPU A1SJCPU (S3) A1SJ71PB92D A1SJHCPU Extension cable A1SC[ ]B Extension base unit A1S6[ ]B(S1)/A1S5[ ]B(S1) (2) For the compact building block type CPU...
  • Page 17 2. SYSTEM CONFIGURATION MELSEC-A (4) For the QCPU (A mode) QCPU (A mode) Basic base unit A1SJ71PB92D QA1S3[ ]B Extension cable QC[ ]B Extension base unit QA1S6[ ]B...
  • Page 18 2. SYSTEM CONFIGURATION MELSEC-A Applicable System The modules and software programs used on A1SJ71PB92D/AJ71PB92D are shown below. (1) Applicable CPU modules The following table indicates the CPU modules that can be used with the A1SJ71PB92D/AJ71PB92D. (a) A1SJ71PB92D Applicable CPU Modules...
  • Page 19 GX Configurator-DP Version 5 or later Write disabled *1 The software version usable by the A1SJ71PB92D/AJ71PB92D is A1SJ71PB92D (F or later) or AJ71PB92D (B or later). When A1SJ71PB92D (software version E or earlier) is used, write is disabled. *2 For the A1SJ71PB92D of software version D or earlier, the extended service mode (MODE E) is not applicable.
  • Page 20 MELSEC-A Precautions for Configuring a System (1) Precaution for parameter writing (a) If a parameter is written to the A1SJ71PB92D/AJ71PB92D that is exchanging I/O data, the I/O data communication is suspended. It is restarted after completion of parameter writing. (b) Do not change the operation mode from the sequence program during parameter writing.