9 MAIN POSITIONING CONTROL
Setting item
Da.1
Operation pattern
Control method
Da.2
Acceleration time
Da.3
No.
Deceleration time
Da.4
No.
Positioning address/
Da.5
movement amount
Arc address
Da.6
Command speed
Da.7
Dwell time
Da.8
M code
Da.9
* Refer to section "5.3 List of positioning data" for information on the setting details.
Positioning data setting example
The following table shows setting examples when "2-axis circular interpolation
control with auxiliary point designation (INC circular interpolation)" is set in
positioning data No. 1 of axis 1. (The required values are also set in positioning
data No. 1 of axis 2.)
Axis 1
Axis 2
Axis
(reference
(interpolation
axis) setting
axis) setting
example
example
Positioning
complete
INC circular
interpolation
1
0
80000.0
60000.0
µ m
µ m
40000.0
30000.0
µ m
µ m
6000.00
mm/min
500ms
10
POINT
Set a value in " Da.7 Command speed" so that the speed of each axis does not
exceed the " Pr.7 Speed limit value". (The speed limit does not function for the
speed calculated by the AD75 during interpolation control.)
Set "Positioning complete" assuming the next positioning
–
data will not be executed.
Set increment system, 2-axis circular interpolation control
–
with auxiliary point designation.
Designate the value set in " Pr.26 Acceleration time 1" as
–
the acceleration time at start.
Designate the value set in " Pr.9 Deceleration time 0" as
–
the deceleration time at deceleration.
Set the movement amount. (Assuming that the " Pr.1 Unit
setting" is set to "mm".)
Set the auxiliary point address. (Assuming that the " Pr.1
Unit setting" is set to "mm".)
Set the speed during movement. (Designate the composite
–
speed in " Pr.21 Interpolation speed designation method".)
Set the time the machine dwells after the positioning stop
–
(position command output stop) to the output of the
positioning complete signal.
Set this when other auxiliary operation commands are
–
issued in combination with the No. 1 positioning data.
9 - 39
MELSEC-A
Setting details