12 CONTROL AUXILIARY FUNCTIONS
Setting item
Setting for the
restart allowable
Pr.150
range when
servo OFF to
ON
* *Refer to section "5.2 List of parameters" for the setting details.
" Pr.150 Setting for the restart allowable range when servo OFF to ON" cannot be set with the AD75TU
whose software version is "C" or earlier.
[Operation at emergency stop input]
Emergency stop input
(Last command position)
2)
Setting of "
Pr.150
OFF to ON"
To enable or disable a restart at servo OFF to ON, set the "movement
range during servo OFF" in the following parameter.
The set data is validated at the rising edge (OFF to ON) of the PLC
READY signal (Y1D).
Setting
value
Restart not allowed
Restart allowed
(c) Precautions for restart at servo OFF to ON
1) To restart operation by servo OFF to ON, the difference between the
last command position and current value is output once at servo ON.
If the setting for the restart allowable range when servo OFF to ON is
large at this time, overload occurs in the machine system such as the
servo side.
Make the setting for the restart allowable range when servo OFF to ON
within the range where the machine system is not affected by the
output provided once.
Stop position
at servo OFF
Movement during
servo OFF
2) A restart at servo OFF to ON is valid at the servo OFF to ON performed
at the first time.
At the servo OFF to ON performed at the second time or later, "
Setting for the restart allowable range when servo OFF to ON" is
ignored.
3) Perform servo OFF in the status where the machine system has
stopped completely.
A restart at servo OFF to ON is not applicable to the system where the
machine system is operated by external pressure, etc. during servo
OFF.
12 - 42
Setting for the restart allowable range when servo
Setting details
Set "0: Restart not
allowed".
Set the restart allowable
movement range during
servo OFF, 1 to 163840
(pulses).
[Operation at restart]
Restart operation
Last command
position
Output once
at restart
MELSEC-A
Buffer memory address
Axis 1 Axis 2 Axis 3
64
214
364
65
215
365
(Current value at servo ON)
Stop position at servo OFF
Pr.150