Download Print this page

Mitsubishi A1SD75M3 User Manual page 376

Positioning module

Advertisement

9 MAIN POSITIONING CONTROL
Cannot be used in the absolute
position detection system.
At power-on or reset, the current
value cannot be restored normally.
(3) Absolute position detection system
The positioning address is the address of the position reached by the machine
zero point return, and its range is 0 ° to 359.99999 ° .
The range 0 ° to 359.99999 ° also applies to the case where the zero point
position is not 0 ° .
<When the mode for absolute position restoration is the "standard
mode" ("
Md.121
For positioning in the same direction, out of bound control (when the
address increases: 359.99999 ° to 0 ° /when the address decreases: 0 ° to
359.99999 ° ) cannot be performed.
Zero point
To make the software stroke limit valid, set the upper and lower limit values
within the range 0 ° to 359.99999 ° .
<When the mode for absolute position restoration is the "infinite
length mode" ("
For positioning in the same direction, out of bound control (when the
address increases: 359.99999 ° to 0 ° /when the address decreases: 0 ° to
359.99999 ° ) can be performed.
Zero point
Make the software stroke limit invalid.
For details of the mode for absolute position restoration, refer to section "12.6.2
Absolute position restoration mode switching function".
Absolute position restoration mode"=0)>
359.99999
359.99999
0
0
Absolute position restoration mode"=1)>
Md.121
359.99999
359.99999
0
0
9 - 18
MELSEC-A
Cannot be used in the absolute
position detection system.
At power-on or reset, the current
value cannot be restored normally.
Range usable in the absolute position
detection system.
(0 to 359.99999 )
Out of bound positioning control can
be performed.
(Infinite length positioning control)

Hide quick links:

Advertisement

loading

This manual is also suitable for:

A1sd75m2A1sd75m1Ad75m2Ad75m1Ad75m3