10 ADVANCED POSITIONING CONTROL
50th point
2nd point
1st point
Setting item
Setting item
b15
b8
b7
b0
Da11 Start positioning data No.
Da10 Shape
b8
b7
b15
b0
D a 12 S pe cia l sta rt
Da13 Parameter
co m m and
No.10
No.2
Condition identifier
No.1
Setting item
Setting item
Condition identifier
b15
b12
b11
b8
b7
b0
Da15 Condition
Da14 Condition target
operater
Open
Da16 Address
Da17 Parameter1
Da18 Parameter2
Open
7001
Set in AD75 the "start block data" and "condition data" corresponding to the following
"block Nos. 7001 to 7010" using the AD75 software package. (The following drawing
shows an example for axis 1.)
Setting item
Setting item
* Setting is only possible when the AD75 software package is used.
(Same for axis 2 and axis 3.)
10 - 5
MELSEC-A
50th point
Setting item
2nd point
1st point
Setting item
Setting item
b15
b8
b7
b0
Da11 Start positioning data No.
Da10 Shape
b15
b8
b7
b0
D a 12 S pe cia l start
Da13 Parameter
co m m and
No.10
Setting item
No.2
Condition identifier
No.1
Setting item
Setting item
Condition identifier
b15
b12
b11
b8
b7
b0
Da15 Condition
Da14 Condition target
operater
Open
Da16 Address
Da17 Parameter1
Da18 Parameter2
Open
7010