12 CONTROL AUXILIARY FUNCTIONS
(a) Set the movement range of section A as follows.
(b) Set the movement range of section B as follows.
(7) Setting when the control unit is "degree"
Current value address
The " Md.29 Current feed value" address is ring addresses between 0 and
359.99999 ° .
0°
Fig. 12.17 Current value address when the control unit is "degree".
Setting the software stroke limit
The upper limit value/lower limit value of the software stroke limit is a value
between 0 and 359.99999 ° .
(1) Setting when the software stroke limit is to be validated.
When the software stroke limit is to be validated, set the upper limit value in a
clockwise direction from the lower limit value.
Lower limit
315º
Section B
•
Software stroke limit lower limit value ................ 315.00000
•
Software stroke limit upper limit value................ 90.00000
•
Software stroke limit lower limit value ................ 90.00000
•
Software stroke limit upper limit value................ 315.00000
Fig. 12.18 Software stroke limit when the control unit is "degree"
359.99999°
359.99999°
0°
0°
Set in a clockwise direction
Section A
Upper limit
90º