12 CONTROL AUXILIARY FUNCTIONS
V
Positioning
control start
Command in-position flag
[ Md. 40 Status: b2]
(2) Precautions during control
(a) A command in-position width check will not be carried out in the following
cases.
•
During deceleration by a stop command or sudden stop command.
•
During speed control, or during the speed control of speed/position
changeover control.
Command in-position
width setting value
OFF
Execution of the command in-position width check
Fig. 12.42 Command in-position width check
(b) The command in-position flag will be turned OFF in the following cases.
("0" will be stored in " Md.40 Status: b2".)
•
At the positioning control start
•
At the speed control start
•
At the zero point return control start
•
At the JOG operation start
•
When the manual pulse generator operation is enabled.
(c) The " Pr.17 Command in-position width" and command in-position flag
( Md.40 Status: b2) of the reference axis are used during interpolation
control.
Speed to position changeover
Speed/position
changeover
control start
ON
12 - 93
MELSEC-A
Command in-position
width setting value
Execution of the command in-position
width check
t