14 TROUBLESHOOTING
Relevant buffer memory
address
Axis 1
Axis 2
Axis 3
Increase the acceleration/deceleration time
constant.
Increase the setting of " Pr.113 Position loop
113
263
413
gain 1".
Refer to the error code 2051-3.
Torque limit setting value
1. Check the droop pulse value and
24
174
324
cumulative regenerative load factor value in
the monitor mode.
Zero point return torque
Check if the values have changed at the
limit value
time of motor stop.
86
236
386
2. Check the torque limit value.
Torque output setting value
Check if the servo torque setting is smaller
1180
1230
1280
than external force.
Check if the machine struck something.
Refer to the error code 2050-5.
Checking method
14 - 41
Remedy
Increase the acceleration/deceleration time constant.
Set a proper value.
1. Change the torque limit value.
2. Reduce the load.
3. Increase the capacity.
Reconsider the operation pattern.