5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.42 Target speed
Md.43 Zero point absolute position
Md.44 Movement amount after
near-point dog ON
Md.45 Torque limit stored value
During operation with positioning data
During interpolation
During JOG operation
During manual pulse generator operation : "0" is stored.
The "zero point absolute position" address is stored.
"0" is stored when the power is turned ON, and the zero point return basic
parameter " Pr.47 Zero point address" is stored when the machine zero point
return is completed.
The zero point absolute position value is changed when the current value charge
function is executed.
"0" is stored when machine zero point return starts.
After machine zero point return starts, the movement amount from the near-point
dog ON to the machine zero point return completion is stored.
(Movement amount: Movement amount to machine zero point return completion
using near-point dog ON as "0".)
The " Pr.18 Torque limit setting value" or " Cd.30 New torque value" is stored.
During positioning start, JOG operation start, manual pulse generator operation
...The " Pr.18 Torque limit setting value" is stored.
When value is changed to " Cd.30 New torque value" during operation
...The " Cd.30 New torque value" is stored.
5 - 154
Storage details
: The actual target speed, considering
the override and speed limit value,
etc., is stored. "0" is stored when
positioning is completed.
: The composite speed or reference
axis speed is stored in the reference
axis address, and "0" is stored in the
interpolation axis address.
: The actual target speed, considering
the JOG speed limit value for the
JOG speed, is stored.
MELSEC-A