5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.117 Regenerative load ratio
Md.118 Effective load ratio
*1
Md.119 Peak load ratio
Md.120 FeRAM access count
Md.121 Absolute position
restoration mode
*1: During any of the following processings, " Md.117 Regenerative load ratio", " Md.118 Effective load ratio" and
" Md.119 Peak load ratio" storage buffer memory data are not updated.
During the processing, therefore, a delay may occur in the updating of the " Md.117 Regenerative load ratio", " Md.118
Effective load ratio" and " Md.119 Peak load ratio" storage buffer memory data.
When a machine zero point return is made (when ZCT is read, when the absolute position reference point is read)
When initial communication is being made with the servo amplifier
When the PLC READY signal [Y1D] is turned from OFF to ON
When the servo parameters are updated with the "AD75M servo position control gain function" of GX Configurator-AP
(For details of GX Configurator-AP, refer to the GX Configurator-AP Operating Manual.)
The average value of the ratios of the regenerative load to the allowable value of
the regenerative brake resistor selected in the servo basic parameter for the past
*1
15 seconds is stored. (Unit: 1%)
The update timing is 1 second interval.
The average value of the ratios of the load to the rated torque of the servomotor
*1
for the past 15 seconds is stored. (Unit: 1%)
The update timing is 1 second interval.
The held value of the ratio of the peak load to the rated torque of the servomotor
is stored. (Unit: 1%)
The update timing is 1 second interval.
The FeRAM access count is stored.
The value is incremented by "3" at power-on.
Increase of the value at a machine zero point return in the absolute position
detection system
(a) When " Md.121 Absolute position restoration mode" is switched between the
"standard mode" and "infinite length mode", the value is incremented by "4".
(b) When " Md.121 Absolute position restoration mode" is not switched, the
value is incremented by "2".
The update timing is 56.8ms.
The mode for absolute position restoration is stored in the axis where " Pr.1
Unit setting" is "2: degree" and absolute position detection is valid.
(Set timing)
At power-on
At completion of machine zero point return
The update timing is 56.8ms.
Refer to section 12.6.2 for details of mode switching for absolute position
restoration.
Storage details
5 - 166