4 INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT
(Step 5) Internal information 2 monitor
1) The AD75 OS version will appear on the 17-segment LED for reference.
[V000]
Version
2) The axis display LED for each axis will turn OFF.
3) When the mode switch is pressed, the state will shift to the input information
n monitor state described in (Step 6).
(Step 6) Input information n monitor
1) Each time the mode switch is pressed, the following input signal names will
sequentially appear on the 17-segment LED.
2) The signal state of each axis displayed on the 17-segment LED is displayed
with the axis display LED for each axis.
Confirm that the display matches each signal state.
When signal is ON ........................ Axis display LED turns ON
When signal is OFF....................... Axis display LED turns OFF
17-segment LED
SVON
ULMT
LLMT
V-P
DOG
(Step 7) Shifting to operation monitor 1, and ending the operation
monitor
1) When the mode switch is pressed, the state will return to the operation
monitor 1 (Step 2).
Each time the mode switch is then pressed, the operation monitors between
(Step 2) and (Step 6) will be repeated.
2) To end the operation monitor, enter the monitor state between (Step 2) and
(Step 6) required by the user.
POINT
(1) The operation monitor described in this section is a function that allows the
AD75 state, control state of each axis and state of the input signals to be
confirmed. This monitor can be operated at any time.
(2) If the AD75 is not operating correctly, use the operation monitors as necessary.
(3) As another display on the above 17-segment LED, if a watch dog timer error
occurs in the AD75, "FALT" will appear.
If a watch dog timer error occurs in the AD75, the PLC CPU must be reset.
If the watch dog timer error still occurs in the AD75 even after resetting the PLC
CPU, the AD75 module must be replaced.
Contact your nearest dealer or sales office.
Target signal name
Servo ON ( Md.116 Servo status: b1)
Upper limit signal
Lower limit signal
Speed/position changeover signal
Near-point dog signal