12 CONTROL AUXILIARY FUNCTIONS
Setting item
Servo OFF
Cd.100
command
* Refer to section "5.7 List of control data" for the setting details.
(2) Servo OFF method
Servo OFF includes all axe servo OFF and axis-by-axis servo OFF.
(a) All axes servo OFF commands the servo amplifiers of all axes to perform
servo OFF.
Turn OFF the all axes servo ON signal (Y15) when the " Md.35 Axis
operation status" of all axes are in any of the following statuses. (The servo
ON signal is ignored if it is turned OFF while any other axis is operating.)
Standby
Stop
Step standby
Step stop
Error occurrence
Step error occurrence
(b) Axis-by-axis servo OFF performs the servo OFF of only any of the axes
when the all axes servo ON signal (Y15) is ON (during all axes servo
ON).When the " Md.35 Axis operation status" of the axis whose servo will
be switched OFF is in any of the following statuses, set the data indicated in
the following table.
Standby
Stop
Step standby
Step stop
Error occurrence
Step error occurrence
Setting
value
1
Set "1: Servo OFF".
Setting details
12 - 39
MELSEC-A
Buffer memory address
Axis 1 Axis 2 Axis 3
1179
1229
1279