Download Print this page

Mitsubishi A1SD75M3 User Manual page 540

Positioning module

Advertisement

12 CONTROL AUXILIARY FUNCTIONS
(6) When "
Da.2
Control method" "0D
Speed control (reverse run)" is to be executed, "
during speed control" must be set to "1: Update current feed value". If either of
the above control methods is executed at the setting of other than "1", an error
"control method setting error" (error code: 524) occurs.
(7) If the servomotor shaft has rotated more than 15000 turns without the AD75
and servo amplifier making communication, e.g. at power-off, absolute position
restoration may not be made normally at the next power-on.
If external force, etc. may cause the servomotor shaft to rotate more than
15000 turns, use the servomotor equipped with brake, for example, to secure
the servomotor shaft.
(8) When any of the following parameters has been changed from the setting at
execution of a machine zero point return, always make a machine zero point
return. If a machine zero point return is not executed, normal absolute position
restoration cannot be performed.
(a) Basic parameters 1
Pr.1
Unit setting,
amount per rotation,
(b) Detailed parameters 1
Pr.13
Software stroke limit upper limit value,
Pr.14
Software stroke limit lower limit value
(c) Zero point return basic parameters
Pr.47
Zero point address
(d) Zero point return detailed parameters
Pr.59
Absolute position restoration selection
(e) Servo basic parameters*
Pr.101
Amplifier setting,
*: When the servo basic parameters in above (e) are changed after the AD75
and servo amplifier has started communication, power the AD75 or servo
amplifier OFF, then ON and make communication between the AD75 or servo
amplifier.
(9) If either of the following settings is made with " Md.121 Absolute position
restoration mode" set to "1: infinite length mode" and "
position restoration selection" set to "1: infinite length mode", an error occurs
when the PLC READY signal (Y1D) turns from OFF to ON.
(a) When "
Pr.1
Error "outside unit setting range" (error code: 900)
(b) When the software stroke limit function (refer to section 12.4.3) is set valid
Error "software stroke limit upper limit" (error code: 921), error "software
stroke limit lower limit" (error code: 922)
(10)Every time a machine zero point return is executed, " Md.120 FeRAM access
count" increases as described below.
(a) When " Md.121 Absolute position restoration mode" is switched between the
"standard mode" and "infinite length mode"
" Md.120 FeRAM access count" increases by "4".
: Speed control (forward run)" or "0E
H
Pr.2
No. of pulses per rotation,
Pr.4
Unit magnification
Rotation direction
Pr.107
Unit setting" is set to other than "2: degree"
12 - 68
MELSEC-A
Pr.22
Current feed value
Movement
Pr.3
Pr.59
Absolute
:
H

Hide quick links:

Advertisement

loading

This manual is also suitable for:

A1sd75m2A1sd75m1Ad75m2Ad75m1Ad75m3