6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Positioning start signal
Axis stop signal
PLC READY signal
AD75 READY signal
Start complete signal
BUSY signal
Positioning complete signal
Error detection signal
(5) Time chart for restarting
V
[Y10]
[Y13]
[Y1D]
[X0]
[X1]
[X4]
[X7]
[XA]
Md.35 Axis operation status
Cd.11 Positioning start No.
Fig. 6.13 Time chart for restarting
0
8
0
6 - 35
MELSEC-A
Dwell time
8
1
1
0
t