5 DATA USED FOR POSITIONING CONTROL

5.4 List of start block data

Before explaining the start block data setting items Da.1 to Da.13 , the configuration
of the start block data will be shown below.
The start block data stored in the AD75 buffer memory has the following type of
configuration.
2nd point
1st point
b15
Da.10
Shape
b15
Da.12
Special start
command
2nd point
1st point
b15
Da.10
Shape
b15
Da.12
Special start
command
50th point
Setting item
Setting item
Buffer memory
Setting item
address
b8
b7
b0
Da.11
Start data No.
b8
b7
b0
Da.13
Parameter
50th point
Setting item
Setting item
b8
b7
b0
Da.11
Start data No.
b8
b7
b0
Da.13
Parameter
Buffer memory
address
Buffer memory
ddress
4349
4301
4300
4399
4351
4350
Setting item
Buffer memory
ddress
Buffer memory
address
4551
4550
4601
4600
5 - 127
MELSEC-A
Up to 50 start block data points can be set
(stored) for each axis in the buffer memory
address shown on the left.
One start block data item is configured of
the items shown in the bold box.
Buffer memory
address
4599
4649